When working in demanding circumstances and time is of the essence, you want to ensure a safe work environment above all.
The Twin-pump principle generates a separate flow for your lifting and traversing part of the operation, ensuring a safe & controlled way of work for your operation.
Standard supplied with:
Details | ||
Articlenumber | 101.002.783 | |
Basic specifications | ||
model | 06 T 25 E | |
max. working pressure | 550 / 55 (bar/Mpa) | 7977 psi |
Performance | ||
number of stages | 1 | |
first stage pressure range max. | 7977 psi | |
first stage pressure range | 0 - 550 / 0 - 55 (bar/Mpa) | 0 - 7977 psi |
first stage output / min. | 600 cc | 20.3 oz |
capacity oil tank (effective) | 25000 cc | 845.4 oz |
number of outputs | 2 | |
General specifications | ||
operator type | electric motor | |
engine | 400 VAC - 1.5 kW - 50 Hz - 3 Ph | |
speed | 2835 rpm | |
Dimensions, weight and temperature | ||
weight, ready for use | 88 kg | 194 lb |
dimensions (LxWxH) | 666 x 440 x 706 mm | 26.2 x 17.3 x 27.8 in |
Technical drawing dimensions | ||
dimension A | 666 mm | 26.2 in |
dimension B | 440 mm | 17.3 in |
dimension C | 706 mm | 27.8 in |